Send feedback
Report an error

Danfoss electromagnetic valves provide efficient control and regulation of the flow of liquids and gases. They are classified based on their mode of operation such as: direct acting valves, servo-operated valves, and pilot operated valves. They are designed for use in liquid, suction, and hot gas pipelines, as well as in condensing units and multi-compressor systems, in all refrigeration, freezing, and air conditioning applications.

Parameters

Performance

All

All

All

All

All

EVO

EVO

Danfoss
Refrigerant:
R22, R134a, R290, R32, R404A, R407A, R407C, R407F, R410A, R448A, R449A, R450A, R452A, R452B, R454A, R454B, R454C, R455A, R507, R513A, R600a, R744 (CO₂), R1234yf
Inlet connection type:
Soldered
Function:
Normaly closed
Maximum working pressure [bar]:
45
Valve coil included:
BB230AS
EVR

EVR

Danfoss
Refrigerant:
R22, R134a, R290, R32, R404A, R407A, R407C, R407F, R410A, R448A, R449A, R450A, R452A, R452B, R454A, R454B, R454C, R455A, R507, R513A, R600a, R744 (CO₂), R1234yf
Inlet connection type:
Flare, Soldered, Flange
Function:
Normaly open, Normaly closed
Maximum working pressure [bar]:
32 - 45
EVRA

EVRA

Danfoss
Refrigerant:
R22, R134a, R404A, R407A, R407C, R407F, R410A, R507, R717 (ammonia)
Inlet connection type:
Welded, Flange
Function:
Normaly closed
Maximum working pressure [bar]:
42
EVRAT

EVRAT

Danfoss
Refrigerant:
R22, R134a, R404A, R407A, R407C, R407F, R410A, R717 (ammonia)
Inlet connection type:
Flange
Function:
Normaly closed
Maximum working pressure [bar]:
42
EVRC

EVRC

Danfoss
Refrigerant:
R134a, R407C, R507
Inlet connection type:
Soldered
Function:
Normaly closed
Maximum working pressure [bar]:
32 - 35
EVRP

EVRP

Danfoss
Refrigerant:
R134a, R290, R407A, R410A
Inlet connection type:
Soldered
Function:
Normaly closed
Maximum working pressure [bar]:
42
EVRS

EVRS

Danfoss
Refrigerant:
R22, R134a, R404A, R407A, R407C, R407F, R410A, R717 (ammonia), R744 (CO₂)
Inlet connection type:
Welded, Thread
Function:
Normaly closed
Maximum working pressure [bar]:
50
EVRST

EVRST

Danfoss
Refrigerant:
R22, R134a, R404A, R407A, R407C, R407F, R410A, R717 (ammonia), R744 (CO₂)
Inlet connection type:
Welded
Function:
Normaly closed
Maximum working pressure [bar]:
50

Danfoss electromagnetic valves provide efficient control and regulation of the flow of liquids and gases. They are classified based on their mode of operation such as: direct acting valves, servo-operated valves, and pilot operated valves. They are designed for use in liquid, suction, and hot gas pipelines, as well as in condensing units and multi-compressor systems, in all refrigeration, freezing, and air conditioning applications.

Electromagnetic valves are adapted to work with most refrigerants (CFC, HCFC, and HFC) as well as high-pressure refrigerants such as R410A and CO2. They can be supplied as normally open or normally closed and with or without manual opening.

Valves are characterized by high reliability and durability due to maximum internal and external tightness. A wide range of coils with different control voltages and various degrees of IP protection enables their application in humid environments and in explosion-hazardous areas. Due to their fast action, they are indispensable in leak/leakage prevention systems.

Solenoid valves applications:

  • Traditional refrigeration systems
  • Industrial refrigeration systems
  • High-pressure installations
  • Heat pump systems
  • Air conditioning devices
  • Liquid coolers
  • Mobile refrigeration systems
  • Chillers with reversible circuits

Due to frequent changes and updates, presented data are provided on illustrative basis only. All materials contained on this website are protected by copyright and their use, copying and publishing in any form is prohibited without the written consent of Elektronika DP Elektronika JSC. Please read the full Terms of use

Sales of equipment

We are a direct importer, an authorized distributor of the world's leading manufacturers of refrigeration equipment and components for refrigeration. The main activity is the selection and sale of equipment and components for refrigeration systems.

Check our offer

Technical support

We actively support our installers. We organize product training and technical consultations for refrigeration engineers at every stage of project implementation. Hundreds of successful investments confirm our competence and experience.

Check our offer

Own production

Based on many years of experience of our engineers in the field of design and assembly of refrigeration equipment, in 2017 we started own production. refrigeration units and multi-compressor units based on Danfoss, Frascold and Bitzer compressors.

Check our offer

Cookies information

This website uses cookies to improve the quality of the services provided. It also uses the Third-Party cookies, they provide tools and solutions that improve the ergonomics and functionality of the website, such as video playback, website usage analytics and marketing content customization.

By clicking accept, you agree to use cookies, as outlined in our Cookie Policy